index plan system_wiring siemens
Siemens
Using a Siemens motor inverter with an Lithiumate BMS.
Function
| BMS
| Motor driver
| Connection
| BMS configuration
| Notes
|
Drive disable
| LLIM /pin 10
| Emergency off / Notaus / Pin 2
| Direct
| Set normally open, Limit grounded (default)
| REQUIRED
|
Regen disable
| HLIM /pin 11
| Brake pedal wiper / Schleifer Bremsgeber / Pin 17
| Place 1 kOhm resistor between pot wiper and pin 17 of motor driver; wire BMS directy to motor driver.
| Set normally open, Limit grounded (default)
| REQUIRED
|
End of charge step reduction
| FLT /pin 12
| Power reduction / Leistungsreduzierung / Pin 20
| Direct
| Set FLT out as a Warning out. Set normally open, warning grounded (default)
| Optional
|
End of charge gradual reduction
| DCL /pin 14
| Accelerator pedal wiper / Schleifer Fahrgeber / Pin 34
| Place 1 kOhm resistor between pot wiper and pin 34 of motor driver. Place diode, between BMS and motor driver, anode to motor driver.
| Set 5 V OK down to 0 V disable (default)
| Optional
|
Function
| BMS
| Motor driver
| Connection
| BMS configuration
| Notes
|
Drive disable
| LLIM /pin 10
| Emergency off / Notaus / Pin 19
| Direct
| Set normally open, Limit grounded (default)
| REQUIRED
|
Regen disable
| HLIM /pin 11
| Regen disable / ??? / Pin 37
| Direct
| Set normally open, Limit grounded (default)
| REQUIRED
|
End of charge step reduction
| FLT /pin 12
| Power reduction / Leistungsreduzierung / Pin 36
| Direct
| Set FLT out as a Warning out. Set normally open, warning grounded (default)
| Optional
|
End of charge gradual reduction
| DCL /pin 14
| Accelerator pedal wiper / Schleifer Fahrgeber / Pin 7
| Place 1 kOhm resistor between pot wiper and pin 7 of motor driver. Place diode, between BMS and motor driver, anode to motor driver.
| Set 5 V OK down to 0 V disable (default)
| Optional
|
|
|