| Symbol
| Item
| Conditions
| Min
| Nom
| Max
| Units
|
| Vabs-max
| Cell voltage absolute maximum rating
| Balance load off
| -0.1 V
| -
| 7.0
| V
|
| Balance load on
| -0.1 V
| -
| 4.2
| V
|
| Vrange
| Cell voltage sensing range
| -
| 2.09
| -
| 4.54
| V
|
| Vresol
| Data communication resolution
| Data link
| -
| 10
| -
| mV
|
| Cell voltage sensing resolution
| 3.2 V
| -
| 19
| -
| mV
|
| Within Vrange
| 7
| -
| 33
|
| Vaccur
| Cell voltage sensing accuracy
| Within Vrange
| -
| +/-10
| +/-15
| mV
|
| Vtemp-err
| Cell voltage sensing error over temp
| Within Vrange -20 to +60°C
| -
| +2 / -7
| +/-18
| mV
|
Within Vrange Charging range: 0 to +60°C
| -
| +/-2
| +/-17
| mV
|
| Isply
| Cell load current
| Stand-by
| -
| -
| 2.0
| uA
|
Active, 1-reading / sec
| -
| 1.5
| 2.0
| mA
|
| Balancing, at 3.6 V (LiFePO4)
| -
| 200
| -
| mA
|
| Balancing, at 4.2 V (LiPo)
| -
| 233
| -
| mA
|
| Trange
| Temperature sensing range
| -
| -99
| -
| +99
| °C
|
| Taccur
| Temperature sensing accuracy
| -
| -
| -
| +/-2
| °C
|
| Toper
| Operating temperature
| -
| -40
|
| 85
| °C
|
| VISOL
| Isolation voltage
| Low voltage to battery End cell boards
| -
| 2500
| -
| V
|
| Ifuse
| Protection fuse current
| Manufactured April 2012 +
| -
| 0.25, Fast
| -
| A
|
| ESD
| ElectroStatic Discharge immunity
| CAN, Unpowered, EIA/JESD22-A115-A waveform with MIL-STD-883, method 3015
|
|
| 6
| kV
|
| All other pins, unpowered, EC/EN/KN 61000-4-2
| 4
|