logo

Lithiumate™ Manual

index reference electrical_specs cell_board_elec_specs

Cell Board electrical specs

General Electrical Specifications for the Cell Boards.

Unless otherwise noted: 25 °C;
Symbol Item Conditions Min Nom Max Units
Vabs-max Cell voltage
absolute maximum rating
Balance load off -0.1 V - 7.0 V
Balance load on -0.1 V - 4.2 V
Vrange Cell voltage sensing range - 2.09 - 4.54 V
Vresol Data communication resolution Data link - 10 - mV
Cell voltage sensing resolution 3.2 V - 19 - mV
Within Vrange 7 - 33
Vaccur Cell voltage sensing accuracy Within Vrange - +/-10 +/-15 mV
Vtemp-err Cell voltage sensing error over temp Within Vrange
-20 to +60°C
- +2 / -7 +/-18 mV
Within Vrange
Charging range: 0 to +60°C
- +/-2 +/-17 mV
Isply Cell load current Stand-by - - 2.0 uA
Active,
1-reading / sec
- 1.5 2.0 mA
Balancing, at 3.6 V (LiFePO4) - 200 - mA
Balancing, at 4.2 V (LiPo) - 233 - mA
Trange Temperature sensing range - -99 - +99 °C
Taccur Temperature sensing accuracy - - - +/-2 °C
Toper Operating temperature - -40 85 °C
VISOL Isolation voltage Low voltage to battery
End cell boards
- 2500 - V
Ifuse Protection fuse current Manufactured April 2012 + - 0.25, Fast - A
ESD ElectroStatic Discharge immunity CAN, Unpowered, EIA/JESD22-A115-A waveform with MIL-STD-883, method 3015     6 kV
All other pins, unpowered, EC/EN/KN 61000-4-2 4

Reported cell voltage graph
Reported cell voltage versus actual cell voltage.
Reported cell voltage versus temperature
Typical error in reported cell voltage versus temperature, at various cell voltages.
e-logo

© 2008~2024 Elithion™, LLC. All rights reserved, except where noted by CC mark. Page published on Jul 19 2013.
The Elithion brand and the 'ə' (upside down 'e') logo are Trademarks of Elithion LLC. Graphic design by morninglori