index plan system_wiring mes_tim MES / CEBI TIM Using a MES / CEBI TIM motor inverter with an Lithiumate BMS. Connect the BMS and the inverter through the CAN bus. In the GUI, go to the "Configure" tab, the "Communicate" sub-tab, the "Message to devices" box, the "Motor driver" box, and select "MES TIM". The TIM inverter does not need any configuration to work with the BMS. However, note that the default CAN bus speed for the TIM is 125 kbps, while for the BMS it is 500 kbps. The speed for both devices can be changed, but it would probably be easiest to change the TIM inverter to 500 kbps. If enabled (see above), the Lithiumate generates the following message for the MES / CEBI TIM series motor inverters. Notes:
Notes:
Notes:
This message is not required, and is not sent by the Lithiumate Pro.