index reference description_specs electrical_specs hd_elec_specs
Lithiumate HD master electrical specs
Electrical Specifications for the 2CN0002E Li-Ion BMS master.
Operation beyond these values will damage the unit
All voltages with respect to pin 1, unless otherwise noted.
Symbol
| Item
| Pins
| Conditions
| Min
|
| Max
| Units
|
VSUPPLY-IN-max
| Power connector, VL or VS supply voltage input
| Power conn., Vload or Vsource
|
| -0.3
|
| 30
| Vdc
|
ISUPPLY-IN-max
| Supply input current
| Power connector, VL or VS supply voltage input
| Continuous
| 0.1
|
| -3.0
| A
|
Peak, inrush
| -10.0
|
IV+-max
| V+ line output current
| Power connector, V+ lines
| Total for all outputs, Continuous
| 0
|
| 3.0
| A
|
Total for all outputs, Peak, inrush
| 6
|
VOPEN-DRAIN-max
| Open Drain output voltage
| Power conn., HLIM, LLIM, FLT, FAN, K1, K2, K3
| Off
|
|
| 40
| V
|
IOPEN-DRAIN-max
| Open Drain output current
| Power conn., HLIM, LLIM, FLT, FAN, K1, K2, K3
| Continuous
| 0.1
|
| -2
| A
|
Peak, inrush
| -4.3
|
VCONT-REQ-IN-max
| Contactor request input voltage
| Control conn., CONTREQ
|
| -0.3
|
| 30
| V
|
VCAN-max
| CAN bus voltage
| Control conn. CANH, CANL
| Between CANL or CANH and CGND
| -0.3
|
| 10
| V
|
Between CANL or CANH and GND
| -100
|
| 100
|
I5V-max
| 5 V line output current
| Control conn., +5V out
|
| -1
|
| 50
| mA
|
IDA-max
| Max D/A converter output current
| Control conn., SOC, CCL, DCL
|
| -10
|
| 10
| mA
|
TAMB
| Ambient temperature
|
| Operating
| -40
|
| +80
| °C
|
ESD
| ElectroStatic Discharge immunity
|
| CAN, Unpowered, EIA/JESD22-A115-A waveform with MIL-STD-883, method 3015
|
|
| 6
| kV
|
All other pins, unpowered, EC/EN/KN 61000-4-2
| 4
|
All voltages with respect to pin 1, unless otherwise noted.
Symbol
| Item
| Pins
| Conditions
| Min
| Nom
| Max
| Units
|
VSUPPLY-IN
| VL or VS supply voltage input
| Power conn., VS or VL
|
| 7
| 12
| 16
| Vdc
|
ISUPPLY-IN
| Supply input current
| Power conn., VS or VL
| Continuous
| -0.15
| -0.2
| -2
| A
|
VOPEN-DRAIN
| Open Drain output voltage
| Power conn., HLIM, LLIM, FLT, FAN, K1, K2, K3
| Off
|
| 30
|
| V
|
IOPEN-DRAIN
| Open Drain output current
| Power conn., HLIM, LLIM, FLT, FAN, K1, K2, K3
| VOPEN-DRAIN < 0.1 V
|
|
| -1.0
| A
|
VCONT-REQ-IN-max
| Contactor request input voltage
| Control conn., CONTREQ
|
| 5
| 12
| 24
| Vdc
|
I5V
| 5 V line output current
| Control conn., +5V out
|
| 0
|
| 30
| mA
|
IDA
| Max D/A converter output current
| Control conn., SOC, CCL, DCL
|
|
| 0
|
| mA
|
Unless otherwise noted: 25 °C; 12 Vdc in
Symbol
| Item
| Conditions
| Min
| Nom
| Max
| Units
|
ISUPL
| Supply current
| No ext loads, 12 Vdc in
|
| 150
| 180
| mA
|
VCONT
| Open Drain output voltage
| IOpen-Drain = 1.0 A
|
|
| 0.1
| V
|
V+
| Supply voltage out
| Vin = 12 V
|
| 11.3
|
| V
|
VFAN-PWM
| Fan PWM output voltage
| Rload > 10 kΩ
|
| TTL (0 & 5)
|
| V
|
VDIG-LIM-LO
| FLT, HLIM< LLIM outputs voltage low
| 10 mA sink
|
|
| 0.1
| V
|
VANALOG
| Analog output voltage (SOC, CCL, DCL)
|
| 0.0
|
| 5.0
| V
|
RANALOG
| Analog output resistance (SOC, CCL, DCL)
|
|
| 100
|
| Ω
|
V5V
| 5 V supply voltage
| -10 mA < I < 10 mA
| 4.9
| 5.0
| 5.1
| V
|
VCTRL-IN-LO
| Control input low voltage threshold
|
|
|
| 0.8
| V
|
VCTRL-IN-HI
| Control input high voltage threshold
|
| 2.0
|
|
| V
|
IHV-CURR-OFFBD
| Current sensor input voltage range
| (1)
| 0.0
| 2.5
| 5.0
| V
|
IHV-CURR_RES
| Current sensor input resolution
|
|
| 0.2
|
| %
|
RCAN_TERM
| CAN termination resistor
| (2)
|
| 120
|
| Ω
|
Notes:
1: Max discharge, 0 current, max charge, respectively
2: May be disconnected if not at the end of CAN bus.
Unless otherwise noted: 25 °C; 12 Vdc in
Symbol
| Item
| Conditions
| Min
| Nom
| Max
| Units
|
FCAN
| CAN speed
|
|
| 125, 250, 500 or 1000
|
| kbs
|
FUSB
| USB baud rate
|
|
| 57.6 k
|
| bps
|
DCfan-PWM
| Fan PWM period
| No fan to full fan
| 0
|
| 100
| %
|
Ffan-PWM
| Fan PWM frequency
|
|
| 10
|
| kHz
|
Tcurr
| Current measurement rate
|
|
| 10
|
| ms
|
Tpwr-up
| Power up time
| From 12 V present to 1st CAN mesage
|
| 13
|
| ms
|
Time between when a set of measurements is taken, and when the readings are available to the Master and for external viewing.
This time depends on the maximum number of cell-boards in a bank, and on the reading rate.
Cell voltages are measured and reported each reading cycle; temperatures, every N cycles, where N is the maximum number of cell-boards in a bank.
Max number of cells in a bank
| 1 reading / s
| 2 reading / s
|
Voltage
| Temperature
| Voltage
| Temperature
|
2
| 0.27 s
| 2 s
| 0.27 s
| 1 s
|
3
| 0.30 s
| 3 s
| 0.30 s
| 1.5 s
|
4
| 0.33 s
| 4 s
| 0.33 s
| 2 s
|
5
| 0.37 s
| 5 s
| 0.37 s
| 2.5 s
|
6
| 0.40 s
| 6 s
| 0.40 s
| 3 s
|
7
| 0.43 s
| 7 s
| 0.43 s
| 3.5 s
|
8
| 0.47 s
| 8 s
| 0.47 s
| 4 s
|
9
| 0.50 s
| 9 s
| 0.50 s
| 4.5 s
|
10
| 0.53 s
| 10 s
| n.a.
|
11
| 0.57 s
| 11 s
| n.a.
|
12
| 0.60 s
| 12 s
| n.a.
|
13
| 0.63 s
| 13 s
| n.a.
|
14
| 0.67 s
| 14 s
| n.a.
|
15
| 0.70 s
| 15 s
| n.a.
|
16
| 0.73 s
| 16 s
| n.a.
|
|
|